Short-Circuit Current Calculation and Selective Protection Scheme Analysis of Fuses in Marine DC Distribution System
ZHOU Ruiping, XIONG Qingwen, ZHANG Xiaoyu
Ship & Boat    2024, 35 (05): 78-85.   DOI: 10.19423/j.cnki.31-1561/u.2024.05.010
Abstract7)      PDF (1794KB)(17)       Save
The calculation method of direct-current (DC) short-circuit current and analysis of selective protection of fuses are important aspects of the design of the DC integrated power system. The design directly affects the selective protection scheme of fuses in the DC distribution system and the operational stability of the DC distribution system. The calculation principle and method of the single module short-circuit current in marine DC distribution system are presented for equivalent calculation of the ship’s DC distribution system. By selecting different short-circuit points, the impact of different short-circuit points on the DC comprehensive power system during short circuit. The short-circuit currents of different branches are calculated to determine the fuse specification through the actual I2T curve of the branch. The error between the simulation results obtained from the equivalent model simulation and the practical calculation is within 1% by analyzing the practical examples. By using the MATLAB/SIMULINK equivalent model simulation method, the calculation of the short-circuit current of the DC distribution system and the reasonable selection of the fuse can be conducted without establishing a detailed SIMULINK model and performing tedious formula calculations.
Reference | Related Articles | Metrics
Analysis of Strength and Fatigue Life of Bolted Base of Marine Diesel Generator Set
BAO Bingcheng, ZHOU Ruiping, LIU Chunhe
Ship & Boat    2022, 33 (01): 74-84.   DOI: 10.19423/j.cnki.31-1561/u.2022.01.074
Abstract173)      PDF (7551KB)(230)       Save
The strength and fatigue life of the bolted base of the marine diesel generator sets are analyzed to ensure its long-term operation reliability. The static strength of the bolted base is calculated based on the finite element modeling of the bolted base. The strength of the base bolts are calculated based on the VDI 2230 standard. The response vibration characteristics of the bolted case under the operating conditions are calculated to analyze its fatigue life according to the base load in the actual vibration test and the rated load. The results show that the static strength of the bolted base calculated by the finite element method meets the requirements, and the bolt strength calculated by the VDI 2230 standard also meets the requirements. The response calculations based on the two methods show that the bolted base will not experience fatigue failure during the 20-year safe operation period.